Servo Driver, three phase 220V 2.0KW, General Type
DA2-200
$626.00Price
Power 2kW Input Power three phase 200-240V Cooling Method Fan Cooling Main circuit control mode Sinusoidal PWM drive Feedback 20Bit INC/17Bit INC Control Mode ①Position control, ②Speed control, ③ Torque control, ④Position/speed mode switch, ⑤Position/torque mode switch, ⑥Speed/torque mode switch, ⑦Positioning operation mode Position Control :Max input pulse frequency Low speed pulse: Max input 500kHz(Line Drive input), Max input 200kHz (Open Collector Input)
High Speed pulse: Max input 4MHz(Line Drive input)Position Control :Command pulse input mode ①Command pulse/command signal , ②Forward rotating pulse and reverse rotating pulse, ③A/B phase orthogonal pulse Position control :Command control mode ①External command pulse input control, ②Internal position data control Electronic Gear Electronic Gear N/M times(N:1~4194304)/M:1~4194304) Torque Limitation Parameter control(Forward rotating and reverse rotating can be set respectively)/External analog torque control Speed control Analog command input VREF 0~±10VDC Speed control Variation Rate ±1r/min or below (load range 0~100%) Speed control: Acceleration and deceleration time setting Acceleration time and deceleration time can be set respectively, and have two groups, and can accelerate and decelerate with S curve Speed control mode External analog input/Internal speed setting Speed control/Torque Limitation Parameter control(Forward rotating and reverse rotating can be set respectively)/External analog torque control Torque control /Analog command input TREF 0~±10VDC Torque control/Torque Limitation Parameter control/External analog speed limitation Input EI1~EI8 8 lines input, the function can be set freely according to the parameter Output Encoder pulse outputs by frequency division, A/B/Z phase output by line drive and open collector (Total 6 lines) EOUT1~EOUT5 5 lines output, the function can be set freely according to the parameter Monitor Feedback speed, reference speed, reference torque, motor current, feedback of current location , Location Difference, reference pulse frequency, Feedback Pulse Accumulation, Reference Pulse Accumulation, VREF input voltage, TREF input voltage, input terminal signal, output terminal signal etc Protection(Alarm display) Overcurrent(Oc1,Oc2),Over speeding (oS), Overvoltage(Hv), Memory Error (dE),Encoder Error(Ec),Overload(oL1,oL2) Main circuit under voltage(Lu),EI Repeat(ctE),Deviation overflow (oF),Servo motor drive overheat(AH) etc. Site location Indoors (Avoid direct sunlight), No corrosive gas (Avoid smoke, methane) Ambient Temperature 0~50 ℃(When the ambient temperature is higher than the required one,please introduce air circulation) Relative humidity RH 90% lower (No condensation) Atmospheric pressure 86~106kPa Vibration ≤0.5G